Pimp my PXE-boot screen
It was “a few” years ago since I did use a HEX-editor… but with a little time over last night I did a small hack to the PXE-boot files.
Why I did it…
1. I wanted to test if I still know how to use a HEX-editor
2. I don’t like the original text.
Do I need to mention: This is NOT supported by anyone and if you break any deployment-solution… don’t blame me.
First, make a backup (*doh*).
The files you are looking for are located on your PXE-point, X:\RemoteInstall\SMSBoot\x86 (and \x64)
I use XVI32 v2.51 www.chmaas.handshake.de/delphi/freeware/xvi32/xvi32.htm to make the changes in the binary files.
Open up PXEBOOT.COM in XVI and search for “Press F12″ (case sensitive).
Then replace the text. If you have a shorter text, fill it out with blank spaces. If you have a longer text… tough luck. :-\
And the changed text:
Save and test to PXE-boot a machine.
(If you can’t see the new text, you probably need to copy the changed file to both the x86 and the x64 directory)
That wasn’t to hard, was it?
If it was… don’t bother to try the WDSNBP.COM-file.
The largest textblock that a user can see is the following text, this is what we want to change / pimp.
If you want to use ascii-art, the maximum width is 51 chars (the width of the third line) and 3 lines high since you need to replace and not add/delete anything.
Of course the first and second line can be a bit longer.
So… start up some texteditor with monospace font (notepad will do) and create some ascii-art.
Start up XVI32 and load WDSNBP.COM, search for “The details below”… now comes the boring/tricky part. Replace the original text with your new ascii-art.
I did a small “translation”-file where I have the orignal row and the new row next to each other, like this for the second row.
There is a search/replace option in XVI32, if you use it remember: replace with the exact same number of characters.
Save, PXE-boot and enjoy…
The original:
The final result:
The MD5-hash of the WDSNBP.COM and PXEBOOT.COM-files in both x86 and x64 directories is the same so you only have to make the changes in one of them.
Why I did it…
1. I wanted to test if I still know how to use a HEX-editor
2. I don’t like the original text.
Do I need to mention: This is NOT supported by anyone and if you break any deployment-solution… don’t blame me.
First, make a backup (*doh*).
The files you are looking for are located on your PXE-point, X:\RemoteInstall\SMSBoot\x86 (and \x64)
I use XVI32 v2.51 www.chmaas.handshake.de/delphi/freeware/xvi32/xvi32.htm to make the changes in the binary files.
Open up PXEBOOT.COM in XVI and search for “Press F12″ (case sensitive).
Then replace the text. If you have a shorter text, fill it out with blank spaces. If you have a longer text… tough luck. :-\
"Press F12 for network service boot"
"Press F12 for snowland deployment "
The original text:"Press F12 for snowland deployment "
And the changed text:
Save and test to PXE-boot a machine.
(If you can’t see the new text, you probably need to copy the changed file to both the x86 and the x64 directory)
That wasn’t to hard, was it?
If it was… don’t bother to try the WDSNBP.COM-file.
The largest textblock that a user can see is the following text, this is what we want to change / pimp.
The details below show the information relating to the PXE boot request for
This computer. Please provide these details to your Windows Deployment Services
Administrator so that this request can be approved.
1 2 3 4 5 6 7 8
12345678901234567890123456789012345678901234567890123456789012345678901234567890
The easy way is just to change the text to something else, but why not use some ascii-art?This computer. Please provide these details to your Windows Deployment Services
Administrator so that this request can be approved.
1 2 3 4 5 6 7 8
12345678901234567890123456789012345678901234567890123456789012345678901234567890
If you want to use ascii-art, the maximum width is 51 chars (the width of the third line) and 3 lines high since you need to replace and not add/delete anything.
Of course the first and second line can be a bit longer.
So… start up some texteditor with monospace font (notepad will do) and create some ascii-art.
__ _ _ __ _ _ _ __ _ _ __
(__ |\ | | | | | | |__| |\ | | \ Deployment Services is loading…
.__) | \| |__| \/\/ |__ | | | \| |__/
1 2 3 4 5 6 7 8
12345678901234567890123456789012345678901234567890123456789012345678901234567890
Now that we have some ascii-art with loads of blank spaces we need to replace the right number of spaces with something that we can see.(__ |\ | | | | | | |__| |\ | | \ Deployment Services is loading…
.__) | \| |__| \/\/ |__ | | | \| |__/
1 2 3 4 5 6 7 8
12345678901234567890123456789012345678901234567890123456789012345678901234567890
###__##_##_##__##_####_#_####__##_##_#__###################################
##(__##|\#|#|##|#|####|#|###|__|#|\#|#|##\##Deployment#Services#is#loading…##
##.__)#|#\|#|__|##\/\/##|__#|##|#|#\|#|__/#########
1 2 3 4 5 6 7 8
12345678901234567890123456789012345678901234567890123456789012345678901234567890
The number of # should be exactly the same as the original text.##(__##|\#|#|##|#|####|#|###|__|#|\#|#|##\##Deployment#Services#is#loading…##
##.__)#|#\|#|__|##\/\/##|__#|##|#|#\|#|__/#########
1 2 3 4 5 6 7 8
12345678901234567890123456789012345678901234567890123456789012345678901234567890
Start up XVI32 and load WDSNBP.COM, search for “The details below”… now comes the boring/tricky part. Replace the original text with your new ascii-art.
I did a small “translation”-file where I have the orignal row and the new row next to each other, like this for the second row.
This computer. Please provide these defails to your Windows Deployment Services
##(__##|\#|#|##|#|####|#|###|__|#|\#|#|##\##Deployment#Services#is#loading…##
Now you can see that the text “computer.” sould be replaced to ” |\ | | “. Yes, it will be hard to read and easy to do wrong.##(__##|\#|#|##|#|####|#|###|__|#|\#|#|##\##Deployment#Services#is#loading…##
There is a search/replace option in XVI32, if you use it remember: replace with the exact same number of characters.
Save, PXE-boot and enjoy…
The original:
The final result:
The MD5-hash of the WDSNBP.COM and PXEBOOT.COM-files in both x86 and x64 directories is the same so you only have to make the changes in one of them.
Read PXEFilter settings from registry
First off… populate HKEY_LOCAL_MACHINE\SOFTWARE\snowland\PXEFilter\ with some strings (ProviderServer, SiteCode, Username, Password, Collection).
Second, edit the pxefilter.vbs and change the following lines:
To this new code:
Now, on startup the filter will read from HKLM to get the settings, if there is an error when reading (no value, no rights) the script will default to “ABC” for sSiteCode and so on…
Second, edit the pxefilter.vbs and change the following lines:
1 | sProviderServer = "" |
2 | sSiteCode = "ABC" |
3 | sNamespace = "root\sms\site_" & sSiteCode |
4 | sUsername = "" |
5 | sPassword = "" |
6 | sCollection = "ABC00004" 'This must be a collection ID, not a collection name |
01 | Function readRegistry(sRegKey, sDefaultValue) |
02 | Dim oWshShell, sVal |
03 | Set oWshShell = CreateObject( "WScript.Shell" ) |
04 | On Error Resume Next |
05 | sVal = oWshShell.RegRead(sRegKey) |
06 | If Err.Number <> 0 Then |
07 | readRegistry = sDefaultValue |
08 | Else |
09 | readRegistry = sVal |
10 | End If |
11 | On Error Goto 0 |
12 | Set oWshShell = Nothing |
13 | End Function |
14 |
15 | Const cKeyPath = "HKEY_LOCAL_MACHINE\SOFTWARE\snowland\PXEFilter\" |
16 | sProviderServer = readRegistry(cKeyPath & "ProviderServer" , "" ) |
17 | sSiteCode = readRegistry(cKeyPath & "SiteCode" , "ABC" ) |
18 | sUsername = readRegistry(cKeyPath & "Username" , "" ) |
19 | sPassword = readRegistry(cKeyPath & "Password" , "" ) |
20 | sCollection = readRegistry(cKeyPath & "Collection" , "ABC00004" ) |
21 | sNamespace = "root\sms\site_" & sSiteCode |
PXE Filter and Obsolete Machines
There is a small problem with the PXE filter and obsolete machines.
Today the PXE-Filter scans the SCCM-database for the machine and doesn’t bother if the machine is obsolete or not… and that might result in problems (The filter adds the obsolete machine to your collection).
Since the PXE-Filter is a VBScript… you can create a small hack…
Around row 150 you will find:
Change that piece of code to:
That will result In a WDSServer.log (If you turn on tracing)
Today the PXE-Filter scans the SCCM-database for the machine and doesn’t bother if the machine is obsolete or not… and that might result in problems (The filter adds the obsolete machine to your collection).
Since the PXE-Filter is a VBScript… you can create a small hack…
Around row 150 you will find:
1 | bFound = False |
2 | Set oClients = oSMS.ExecQuery(sQuery) |
3 | For each oClient in oClients |
4 | bFound = true |
5 | iResourceID = oClient.ResourceID |
6 | PXE.LogTrace "Found existing machine " & oClient.NetbiosName & " with ResourceID = " & iResourceID |
7 | sNetBiosName = oClient.NetbiosName |
8 | Exit For |
9 | Next |
01 | bFound = False |
02 | Set oClients = oSMS.ExecQuery(sQuery) |
03 | For each oClient in oClients |
04 | If oClient.Obsolete = 1 Then |
05 | PXE.LogTrace "Found obsolete machine " & oClient.NetbiosName & ", skipping" |
06 | Else |
07 | bFound = True |
08 | iResourceID = oClient.ResourceID |
09 | PXE.LogTrace "Found existing machine " & oClient.NetbiosName & " with ResourceID = " & iResourceID |
10 | sNetBiosName = oClient.NetbiosName |
11 | Exit For |
12 | End If |
13 | Next |
[4332] 09:49:22: [WDSPXE] [Microsoft.BDD.PXEFilter] Request from 10.26.64.240:67 Len:548
[4332] 09:49:22: [WDSPXE] [Microsoft.BDD.PXEFilter] About to run script
[4332] 09:49:22: [WDSPXE] [Microsoft.BDD.PXEFilter] Processing request from MAC address = 00:1E:0B:34:0F:E7, IP address = 0.0.0.0, UUID = E11832C1-58C0-DC11-BBDA-0B340FE7001E
[4332] 09:49:22: [WDSPXE] [Microsoft.BDD.PXEFilter] Found obsolete machine RIRO003, skipping
[4332] 09:49:22: [WDSPXE] [Microsoft.BDD.PXEFilter] Found existing machine RIRO003 with ResourceID = 112
[4332] 09:49:22: [WDSPXE] [Microsoft.BDD.PXEFilter] Added new membership rule to collection B0100012
[4332] 09:49:22: [WDSPXE] [Microsoft.BDD.PXEFilter] About to run script
[4332] 09:49:22: [WDSPXE] [Microsoft.BDD.PXEFilter] Processing request from MAC address = 00:1E:0B:34:0F:E7, IP address = 0.0.0.0, UUID = E11832C1-58C0-DC11-BBDA-0B340FE7001E
[4332] 09:49:22: [WDSPXE] [Microsoft.BDD.PXEFilter] Found obsolete machine RIRO003, skipping
[4332] 09:49:22: [WDSPXE] [Microsoft.BDD.PXEFilter] Found existing machine RIRO003 with ResourceID = 112
[4332] 09:49:22: [WDSPXE] [Microsoft.BDD.PXEFilter] Added new membership rule to collection B0100012
PXE Filter (v4.1.501)
Got a comment on another post from Thomas who was asking for a version of the PXE Filter that works.
I have used this one on a few installations.
You need to configure:
sProviderServer if you have the PXE point on another server
sSiteCode for your site
sCollection to the collection which you advertise your deployment task sequence
What the PXEFilter does is (in general):
I have used this one on a few installations.
You need to configure:
sProviderServer if you have the PXE point on another server
sSiteCode for your site
sCollection to the collection which you advertise your deployment task sequence
What the PXEFilter does is (in general):
- Check if the machine exist, and if not adds it to the SCCM.
- Checks if the machine is member of a specific collection (sCollection) and if not adds it to the collection (Direct member)
- Waits until the machine can see the advertisment (A maximum of 30 seconds)
001 | ' //*************************************************************************** |
002 | ' // ***** Script Header ***** |
003 | ' // |
004 | ' // Solution: Microsoft Deployment Toolkit |
005 | ' // File: PXEFilter.vbs |
006 | ' // |
007 | ' // Purpose: Decide what needs to be done for each PXE requests received |
008 | ' // by WDS. If not present in the ConfigMgr database, add it. |
009 | ' // |
010 | ' // Usage: (loaded automatically by Microsoft.BDD.PXEFilter DLL) |
011 | ' // |
012 | ' // Microsoft Solution Version: 4.1.501 |
013 | ' // Microsoft Script Version: 4.1.501 |
014 | ' // Customer Build Version: 1.0.0 |
015 | ' // Customer Script Version: 1.0.0 |
016 | ' // |
017 | ' // Microsoft History: |
018 | ' // 4.0.501 MTN 02/19/2008 Added header, additional logging, advertisement |
019 | ' // verification for every request. |
020 | ' // |
021 | ' // Customer History: |
022 | ' // |
023 | ' // ***** End Header ***** |
024 | ' //*************************************************************************** |
025 |
026 | '//---------------------------------------------------------------------------- |
027 | '// |
028 | '// Set global variables, used by the ZTIProcess function below. (Note that |
029 | '// any changes to this script will require restarting the WDS service, since |
030 | '// the script is only loaded once and kept in memory as long as the service |
031 | '// is running.) |
032 | '// |
033 | '// If ConfigMgr is running on the same server as WDS, the sProviderServer |
034 | '// value can be left blank and the sUsername and sPassword values must be |
035 | '// blank. |
036 | '//---------------------------------------------------------------------------- |
037 |
038 | Option Explicit |
039 |
040 | Dim sProviderServer |
041 | Dim sSiteCode |
042 | Dim sNamespace |
043 | Dim sUsername |
044 | Dim sPassword |
045 | Dim sCollection |
046 |
047 | sProviderServer = "" |
048 | sSiteCode = "ABC" |
049 | sNamespace = "root\sms\site_" & sSiteCode |
050 | sUsername = "" |
051 | sPassword = "" |
052 | sCollection = "ABC00004" ' This must be a collection ID, not a collection name |
053 |
054 | '//---------------------------------------------------------------------------- |
055 | '// Main routine |
056 | '//---------------------------------------------------------------------------- |
057 |
058 | ZTIProcess |
059 |
060 | Function ZTIProcess |
061 |
062 | Dim sMacAddress |
063 | Dim sIPAddress |
064 | Dim sUUID |
065 | Dim sNetBiosName |
066 | Dim oLocator |
067 | Dim oSMS |
068 | Dim sQuery |
069 | Dim bFound |
070 | Dim iResourceID |
071 | Dim re |
072 | Dim oSite |
073 | Dim oParams |
074 | Dim oResult |
075 | Dim oLastError |
076 | Dim oClients |
077 | Dim oClient |
078 | Dim oCollection |
079 | Dim oNewRule |
080 | Dim oAdvertisement |
081 | Dim bTrying |
082 | Dim sAdvert |
083 | Dim i |
084 |
085 | ' Initialization |
086 |
087 | sMacAddress = PXE.MacAddress |
088 | sIPAddress = PXE.IPAddress |
089 | sUUID = PXE.UUID |
090 |
091 | Set re = New RegExp |
092 | re.Pattern = ":" |
093 | re.Global = true |
094 | sNetBiosName = "MAC" & re.Replace(sMacAddress, "" ) |
095 |
096 | ' Clear invalid UUID values |
097 |
098 | If sUUID = "00000000-0000-0000-0000-000000000000" or sUUID = "FFFFFFFF-FFFF-FFFF-FFFF-FFFFFFFFFFFF" then |
099 | sUUID = "" |
100 | End if |
101 |
102 | ' Log details |
103 |
104 | PXE.LogTrace "Processing request from MAC address = " & sMacAddress & ", IP address = " & sIPAddress & ", UUID = " & sUUID |
105 |
106 | '//---------------------------------------------------------------------------- |
107 | '// Filter requests. This may need to be customized if you only want some |
108 | '// network segments to be supported. |
109 | '//---------------------------------------------------------------------------- |
110 |
111 | ' Ignore ConfigMgr "ping" requests |
112 |
113 | If PXE.IPAddress = "127.0.0.1" or PXE.MacAddress = "FF:FF:FF:FF:FF:FF" then |
114 | PXE.LogTrace "Ignoring ConfigMgr ping request" |
115 | Exit Function |
116 | End if |
117 |
118 | '//---------------------------------------------------------------------------- |
119 | '// Verify the computer is known to ConfigMgr |
120 | '//---------------------------------------------------------------------------- |
121 |
122 | ' Connect to the SMS provider |
123 |
124 | Set oLocator = CreateObject( "WbemScripting.SWbemLocator" ) |
125 | Set oSMS = oLocator.ConnectServer(sProviderServer, sNamespace, sUsername, sPassword) |
126 |
127 | ' Build the query |
128 |
129 | sQuery = "SELECT * FROM SMS_R_System WHERE MacAddresses = '" & sMacAddress & "'" |
130 | If sUUID <> "" then |
131 | sQuery = sQuery & " OR SMBIOSGUID = '" & sUUID & "'" |
132 | End if |
133 |
134 | ' Process the query |
135 |
136 | bFound = False |
137 | Set oClients = oSMS.ExecQuery(sQuery) |
138 | For each oClient in oClients |
139 | bFound = true |
140 | iResourceID = oClient.ResourceID |
141 | PXE.LogTrace "Found existing machine " & oClient.NetbiosName & " with ResourceID = " & iResourceID |
142 | sNetBiosName = oClient.NetbiosName |
143 | Exit For |
144 | Next |
145 |
146 | '//---------------------------------------------------------------------------- |
147 | '// If necessary, add the computer to the ConfigMgr database |
148 | '//---------------------------------------------------------------------------- |
149 |
150 | If not bFound then |
151 |
152 | PXE.LogTrace "Could not find machine with MAC address '" & sMacAddress & "' or SMBIOS UUID '" & sUUID & "'." |
153 |
154 | ' Add the computer |
155 |
156 | Set oSite = oSMS. Get ( "SMS_Site" ) |
157 | Set oParams = oSite.Methods_.Item( "ImportMachineEntry" ).inParameters.SpawnInstance_() |
158 | oParams.NetbiosName = sNetBiosName |
159 | oParams.SMBIOSGUID = sUUID |
160 | oParams.MACAddress = sMacAddress |
161 | oParams.OverwriteExistingRecord = false |
162 |
163 | On Error Resume Next |
164 | Set oResult = oSite.ExecMethod_( "ImportMachineEntry" , oParams) |
165 | If Err then |
166 | PXE.LogTrace "Error importing machine entry: " & Err.Description & " (" & Err.Number & ")" |
167 | Set oLastError = CreateObject( "WbemScripting.SWbemLastError" ) |
168 | PXE.LogTrace "Last WMI error: " & oLastError.Description |
169 | Exit Function |
170 | End if |
171 | On Error Goto 0 |
172 |
173 | iResourceID = oResult.ResourceID |
174 | PXE.LogTrace "Added new machine with ResourceID = " & iResourceID |
175 |
176 | End if |
177 |
178 | '//---------------------------------------------------------------------------- |
179 | '// Check if the computer is a member of the specified collection |
180 | '//---------------------------------------------------------------------------- |
181 |
182 | If bFound then |
183 |
184 | ' Build the query |
185 |
186 | sQuery = "SELECT * FROM SMS_CM_RES_COLL_" & sCollection & " WHERE ResourceID = " & iResourceId |
187 |
188 | ' Process the query |
189 |
190 | bFound = False |
191 | Set oClients = oSMS.ExecQuery(sQuery) |
192 | For each oClient in oClients |
193 | bFound = true |
194 | PXE.LogTrace "Machine is already in collection " & sCollection |
195 | Exit For |
196 | Next |
197 |
198 | End If |
199 |
200 | '//---------------------------------------------------------------------------- |
201 | '// If necessary, add the computer to the specified collection |
202 | '//---------------------------------------------------------------------------- |
203 |
204 | If not bFound then |
205 |
206 | ' Add the computer to the specified collection |
207 |
208 | On Error Resume Next |
209 | Set oCollection = oSMS. Get ( "SMS_Collection.CollectionID='" & sCollection & "'" ) |
210 | If Err then |
211 | PXE.LogTrace "Error retrieving collection " & sCollection & ": " & Err.Description & " (" & Err.Number & ")" |
212 | Set oLastError = CreateObject( "WbemScripting.SWbemLastError" ) |
213 | PXE.LogTrace "Last WMI error: " & oLastError.Description |
214 | Exit Function |
215 | End if |
216 | On Error Goto 0 |
217 |
218 | Set oNewRule = oSMS. Get ( "SMS_CollectionRuleDirect" ).SpawnInstance_() |
219 | oNewRule.ResourceClassName = "SMS_R_System" |
220 | oNewRule.RuleName = sNetBiosName |
221 | oNewRule.ResourceID = iResourceID |
222 |
223 | On Error Resume Next |
224 | oCollection.AddMembershipRule oNewRule |
225 | If Err then |
226 | PXE.LogTrace "Error adding membership rule to " & sCollection & ": " & Err.Description & " (" & Err.Number & ")" |
227 | Set oLastError = CreateObject( "WbemScripting.SWbemLastError" ) |
228 | PXE.LogTrace "Last WMI error: " & oLastError.Description |
229 | Exit Function |
230 | End if |
231 | On Error Goto 0 |
232 | PXE.LogTrace "Added new membership rule to collection " & sCollection |
233 |
234 | End if |
235 |
236 | '//---------------------------------------------------------------------------- |
237 | '// Wait until an advertisement is seen. |
238 | '//---------------------------------------------------------------------------- |
239 |
240 | ' Check for the advertisements |
241 |
242 | Set oAdvertisement = oSMS. Get ( "SMS_Advertisement" ) |
243 | i = 0 |
244 | bTrying = True |
245 | Do While bTrying |
246 |
247 | Set oParams = oAdvertisement.Methods_( "GetAdvertisements" ).inParameters.SpawnInstance_() |
248 | oParams.ResourceID = iResourceID |
249 |
250 | Set oResult = oAdvertisement.ExecMethod_( "GetAdvertisements" , oParams) |
251 | For each sAdvert in oResult.AdvertisementIDs |
252 | PXE.LogTrace "Found advertisement " & sAdvert |
253 | bTrying = False |
254 | Next |
255 |
256 | i = i + 1 |
257 | If bTrying and i > 10 then |
258 | PXE.LogTrace "Giving up after 30 seconds of checking for new advertisements." |
259 | bTrying = False |
260 | End if |
261 |
262 | PXE.Sleep 3000 |
263 |
264 | Loop |
265 |
266 | PXE.LogTrace "Exiting PXEFilter.vbs" |
267 |
268 | End Function |
BDD2007 PXE-Filter
The PXE-filter in BDD2007 isn’t the best, and there are a few good-to-know things that can be hard to find…
The script \Microsoft Deployment Toolkit\Scripts\PXEFilter.vbs have a few parameters at the top that you need to configure:
Remember: Do not add user and pass when you are on the same machine.
To debug the script, set the following key HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Tracing\WDSSERVER\EnableFileTracing to 1 and restart WDSServer
When you do, it will create a logile at %WinDir%\Tracing\WDSServer.LOG
If you need to add some debug-info in the script, add a line like this:
Then you will se the following line in WDSServer.LOG:
1. Looks to see if the machine exist (via WMI to the SCCM-server)
2. If it exist, just exit the script. If not, create it.
3. Add it to the collection (Stated with the sCollection-setting)
4. Wait’s up to 15 seconds to see if there is an advertisment against the collection.
And then it’s done.
Note: I found this info when using SCCM2007 and BDD2007, might work with other versions…
The script \Microsoft Deployment Toolkit\Scripts\PXEFilter.vbs have a few parameters at the top that you need to configure:
1 | sProviderServer = "sccmserver.domain.com" ' FQDN of the SCCM-server |
2 | sSiteCode = "CS1" ' Your site-code |
3 | sNamespace = "root\sms\site_" & sSiteCode ' Do not change |
4 | sUsername = "" ' Keep this one blank if the WDS and SCCM are installed on the same machine |
5 | sPassword = "" ' Same as with sUsername |
6 | sCollection = "CS10000E" ' ID of the deployment role |
To debug the script, set the following key HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Tracing\WDSSERVER\EnableFileTracing to 1 and restart WDSServer
When you do, it will create a logile at %WinDir%\Tracing\WDSServer.LOG
If you need to add some debug-info in the script, add a line like this:
1 | PXE.LogTrace "My little debug-thingy" |
[5440] 15:34:11: [WDSPXE] [Microsoft.BDD.PXEFilter] My little debug-thingy
And when you get it to work, the WDSServer.LOG should look like this: [6288] 15:34:07: [WDSPXE] [Microsoft.BDD.PXEFilter] About to run script
[1812] 15:34:07: [WDSPXE] [Microsoft.BDD.PXEFilter] PXEFilter.vbs – Processing request from MAC address = 00:11:22:33:44:55, IP address = 0.0.0.0, UUID = 11111111-1111-1111-1111-111111111111
[1812] 15:34:07: [WDSPXE] [Microsoft.BDD.PXEFilter] PXEFilter.vbs – Could not find machine with MAC address ‘00:11:22:33:44:55′ or SMBIOS UUID ‘11111111-1111-1111-1111-111111111111′.
[1812] 15:34:07: [WDSPXE] [Microsoft.BDD.PXEFilter] PXEFilter.vbs – Added new machine with ResourceID = 46
[1812] 15:34:08: [WDSPXE] [Microsoft.BDD.PXEFilter] PXEFilter.vbs – Added new membership rule to collection CS10000E
[1812] 15:34:11: [WDSPXE] [Microsoft.BDD.PXEFilter] PXEFilter.vbs – Found advertisement CS120001
So what does the PXE-filter do?[1812] 15:34:07: [WDSPXE] [Microsoft.BDD.PXEFilter] PXEFilter.vbs – Processing request from MAC address = 00:11:22:33:44:55, IP address = 0.0.0.0, UUID = 11111111-1111-1111-1111-111111111111
[1812] 15:34:07: [WDSPXE] [Microsoft.BDD.PXEFilter] PXEFilter.vbs – Could not find machine with MAC address ‘00:11:22:33:44:55′ or SMBIOS UUID ‘11111111-1111-1111-1111-111111111111′.
[1812] 15:34:07: [WDSPXE] [Microsoft.BDD.PXEFilter] PXEFilter.vbs – Added new machine with ResourceID = 46
[1812] 15:34:08: [WDSPXE] [Microsoft.BDD.PXEFilter] PXEFilter.vbs – Added new membership rule to collection CS10000E
[1812] 15:34:11: [WDSPXE] [Microsoft.BDD.PXEFilter] PXEFilter.vbs – Found advertisement CS120001
1. Looks to see if the machine exist (via WMI to the SCCM-server)
2. If it exist, just exit the script. If not, create it.
3. Add it to the collection (Stated with the sCollection-setting)
4. Wait’s up to 15 seconds to see if there is an advertisment against the collection.
And then it’s done.
Note: I found this info when using SCCM2007 and BDD2007, might work with other versions…